Gozney Dome S1 Natural Gas: What the Manual Says and What It Does Not
7 min read · by Arjun Mehta · Last updated: November 6, 2026
The Gozney Dome S1 natural gas option is not listed in the S1 manual, which gives LPG as the only gas type. The data plate in the Australia and New Zealand technical manual reads LPG at 2.75 kPa with a 1.52 mm jet, and the sections checked for this guide never mention natural gas. Do not assume a later switch is possible.
Check the gas type on your own data plate before you connect a cylinder or any gas line, since a Gozney Dome S1 natural gas rating is not printed there. If the label and this guide do not match, contact Gozney before you use the oven.
This is general information from Gozney’s manual and help content, not installation advice. Gas work must follow your local codes and the manual that shipped with your oven.
Gozney Dome S1 Natural Gas: What the Manual Lists
The Dome S1 manual for Australia and New Zealand lists LPG as the only gas type on its data plate, with no natural gas rating.
The Gozney S1 technical manual prints model 4555-S1-03 on its data plate, with gas pressure 2.75 kPa, a gas rate of 30 MJ/h, gas type LPG and a jet orifice of 1.52 mm. Those four gas lines are the reference for any S1 gas question, and they sit alongside the oven size and heat details in our Gozney Dome S1 dimensions guide.
The manual gives no natural gas rating, and the pages checked for this guide do not describe a natural gas setup. For Gozney Dome S1 natural gas, that means no rating is printed. Until Gozney confirms otherwise in writing, treat the S1 as an LPG-only oven. When you ask a seller or Gozney, quote model 4555-S1-03 and ask them to state the gas type in writing, so the answer matches the label on your unit.

Can a Dome S1 Run on Natural Gas?
Gozney’s help center, as shown in search results, says the S1 is certified for propane only and cannot be used with natural gas.
This guide could read only the search snippet for that help article, because the full page would not open. Confirm the exact wording on Gozney’s help center before you order, and ask the seller to put the gozney dome s1 natural gas answer in writing.
The same snippet says a Dome cannot be adapted or converted to a different fuel after purchase. That matches the data plate, which names one gas type and one jet size for the S1, so a Gozney Dome S1 natural gas setting is not something the owner can select.
According to the same search results, Gozney sells a natural gas Dome in the US only, with an 8.2 kW burner. That is a separate model, not a setting you can change on an S1, so it does not change the S1 answer. If you are comparing other ovens, our Gozney Arc natural gas guide answers the same fuel question for the Arc. Our Gozney Dome manual guide covers the original Dome documents in more detail.
What Gas Setup Does the S1 Manual Describe?
The S1 manual has no Gozney Dome S1 natural gas setting, but it does list a 127 mm flue outlet and says to shut off the gas at the cylinder before you disconnect anything from the oven.
The parts list includes a gas hose and regulator, a gas inlet, a flue pipe and a flue cap. The flue outlet is 127 mm, which is the size to match when you check the flue fit. The hose and regulator come with the oven for LPG use, so they do not make the S1 a natural gas unit.
The manual’s disconnect steps are short. Turn the gas off at the cylinder first, then wait three minutes before you remove the regulator.
For storage or a cylinder exchange, disconnect only the cylinder. The manual covers the cylinder side of the setup, not a fuel change.

How Does the S1 Gas Data Compare With the Original Dome?
For Gozney Dome S1 natural gas questions, pressure is the number people mix up. The original Dome’s US spec sheet lists 30 mbar, while the S1 manual lists 2.75 kPa, which is 27.5 mbar. The two figures are close, but they come from different markets and labels, so compare them with care.
| Item | Dome S1 (AU/NZ manual) | Original Dome (US spec sheet) |
|---|---|---|
| Gas pressure | 2.75 kPa (27.5 mbar) | 30 mbar |
| Gas type on label | LPG | LPG |
| Natural gas | Not in the manual | Separate US model (search snippet) |
The original Dome figures come from the Gozney Dome specification sheet for the US. Read the gas figures on the label of your own unit, because a table from another model cannot confirm what your S1 is rated for.
What Gas Safety Rules Apply?
Whatever the answer on Gozney Dome S1 natural gas, the S1 manual bans use in enclosed areas and sets a 1.5 m distance from structures, combustible material and other gas cylinders.
- Never operate the oven in an enclosed area, because enclosed use can cause asphyxiation, fire or explosion.
- Never leave the oven unattended while it is operating.
- Keep it at least 1.5 m from any structure, combustible material or other gas cylinder.
- Keep it at least 7.5 m from any flammable liquid.
If you smell gas, shut off the gas, put out any open flame and move away from the appliance. If the odor continues, call your fire department immediately, as the manual’s danger notice instructs.
What Should You Check When the Flame Looks Wrong?
The S1 manual says a flame that looks overly yellow or makes more noise than usual can mean debris is blocking the venturi.
Check only when the oven is off, disconnected from the gas and cool. The manual treats a yellow or noisy flame as a maintenance check, not something to fix while the oven is running.
For the oven interior, the manual says it self-cleans above 343 °C, and burnt-on food should burn off after about four hours. A clean oven does not change the gas type on the data plate.
Frequently Asked Questions
Is there a natural gas Gozney Dome S1?
Not according to the S1 manual, which lists LPG only, so no Gozney Dome S1 natural gas model appears in it. Gozney’s help content, seen only in search results, says the S1 is certified for propane only, so confirm the gas type with Gozney before you buy.
Can I convert my Dome S1 to natural gas?
Gozney Dome S1 natural gas conversion is not covered anywhere in the pages checked. The manual gives no conversion steps, and the help snippet says a Dome cannot be converted to a different fuel after purchase. Do not attempt a conversion yourself, because the data plate names one gas type and one jet size for the S1.
What gas pressure does the Dome S1 use?
The data plate, which has no Gozney Dome S1 natural gas entry, lists 2.75 kPa (27.5 mbar) for LPG, a gas rate of 30 MJ/h and a 1.52 mm jet. The manual is written for Australia and New Zealand, so check the label on your own unit before you connect a cylinder.
Can I use the Dome S1 indoors or in a garage?
No. The manual says never to operate the oven in an enclosed area, because enclosed use can cause asphyxiation, fire or explosion. Use it only in an open area, at least 1.5 m from structures and other gas cylinders.
What should I do if I smell gas near the oven?
Shut off the gas, put out any open flames and move away from the oven. If the smell continues, call your fire department immediately, as the manual instructs.
If you need a gozney dome s1 natural gas unit, confirm the fuel in writing with Gozney or the seller before you pay, and do not plan around a later switch. Treat Gozney Dome S1 natural gas as unavailable until Gozney says otherwise in writing. Compare the data plate on the unit that arrives with the manual before you connect anything. For the separate natural gas Dome, read our guide on the original Dome natural gas setup.